excel V+
Vascular and pigment laser system
Designed with input from leading dermatologists, excel V+ is an advanced medical aesthetic laser that delivers the power, precision, and performance practices need to address today’s most in-demand skin concerns. Built for professional use, it enables safe, effective treatment of both vascular and pigmentary indications.1
Dual Wavelength System for Precise Vascular and Pigment Treatments
This dual-wavelength laser system combines two clinically proven wavelengths with large spot sizes up to 16 mm for efficient, precise treatments, with fast spot size changes that don’t require stopping treatment—helping optimize workflow while supporting consistent, high-quality outcomes across a wide range of patient needs.
As a versatile vascular and pigment laser treatment system, excel V+ provides advanced aesthetic laser technology for treating:
High-Power 532 nm & 1064 nm Wavelengths
Four compatible handpieces give you even more versatility with excel V+. Deliver the micro-pulsed 532 nm wavelength with our Genesis V™ handpiece, customize spot size and wavelength using the fully-integrated CoolView™, or use the pencil-like Dermastat handpieces to precisely treat small vascular and pigmented lesions.2
Before and after results
Hear from our customers
"Cutera’s excel V+ has improved our business by boosting patient satisfaction, improving our spectrum of treatment options, and increasing our family/friend referrals. Overall, it has definitely improved our ability to treat patients and their satisfaction with treatment."
"We mostly treat unsightly veins, such as spider veins and small varicose veins, and occasionally hyperpigmented lesions. We often use the excel V+ laser in combination with sclerotherapy and treat those veins that respond best to laser treatments with this device."
"Laser Genesis is one of my cornerstone treatments for patients with concerns about their complexion. It is a fantastic treatment for patients who want to treat redness, lighten pigmentation and even out their overall skin tone, and it improves skin texture through stimulation of collagen production."
Carousel items
Other Solutions
-
The First and Original FDA-Cleared Energy Device for the Treatment of Mild to Severe Acne.
AviClear
-
Skin Revitalization and Resurfacing, Pigmented Lesions, Tattoo Removal
enlighten
-
Hair Removal, Pigmented Lesions, Vascular Lesions
excel HR
-
Skin Revitalization and Resurfacing, Pigmented Lesions, Vascular Lesions
excel V
-
Dynamic Facial Resurfacing and Remodeling
Secret DUO
-
Skin Revitalization and Resurfacing, Pigmented Lesions, Vascular Lesions, Hair Removal
xeo+
-
Skin Revitalization and Resurfacing
Secret PRO
-
Skin Revitalization and Resurfacing
Secret RF
-
Rapid Muscle Sculpting
truFlex
-
Body Sculpting
truSculpt
-
Skin Revitalization and Resurfacing, Pigmented Lesions, Vascular Lesions, Hair Removal
xeo
Indications for use: The excel V+ 532 nm wavelength is indicated for the coagulation and hemostasis of benign vascular and cutaneous lesions in dermatology including, but not limited to, the following general categories: Benign vascular lesions, including angiomas, hemangiomas, port wine stains, venous anomalies, telangiectasia (facial or extremities), leg veins and poikiloderma of Civatte; Benign pigmented lesions, including nevi and lentigines; Benign cutaneous lesions, including warts and scars; Chloasma. The excel V+ 1064 nm wavelength is indicated for the coagulation and hemostasis of benign vascular and cutaneous lesions in dermatology including, but not limited to, the following general categories: Benign vascular lesions, including port wine stains, hemangiomas, warts, telangiectasia, rosacea, venous lake, leg veins, spider veins and poikiloderma of Civatte; Benign cutaneous lesions, including warts, scars and striae; Benign pigmented lesions, including seborrheic keratoses and nevi; Chloasma; Mild to moderate inflammatory acne vulgaris. The 1064 nm wavelength is also indicated for the treatment of wrinkles such as, but not limited to, periocular and perioral wrinkles.
Contraindications: Pregnant patients; Patients undergoing treatment for skin cancer.
Important Safety Information: The following treatment-related expected transient side effects and possible adverse events may occur during or following treatment with excel V+: Erythema; Edema; Purpura; Hyperpigmentation; Hypopigmentation; Burns; Erosion; Epidermal crusting; Blistering; Scarring; Deep tissue injury; Prolonged wound healing; Temporary or permanent gray hair; Stimulation of terminal hair growth; Undesired hair loss in hair-bearing areas; Red rash/bumps; Hemosiderin staining; Textural changes; Cutaneous indentations; Sun exposure, tanning beds, and artificial tanning mat increase the risk of side effects and adverse events.
Warnings: Do not treat over dysplastic nevi or questionable pigmented lesions. Do not treat over or close to tattoos or permanent make-up.
Precautions: Photosensitizing drugs (Tetracyclines, etc.); Be aware that you may have to adjust the treatment parameters according to clinical response from test area(s). Anticoagulants may increase risk of purpura or bruising; History of coagulopathies; History of keloids or hypertrophic scarring; Diabetes may impede wound healing; History of herpes; Pre-treatment with an antiviral may be indicated. Isotretinoin (Accutane/Roaccutan) use; History of vitiligo. Refer to the Operator Manual to view the laser safety labels of the product.